Generator Information

CHOOSING THE BEST GENERATOR FOR THE JOB

These are the things to consider when selecting a generator:

HOW DO YOU PLAN TO USE YOUR GENERATOR?
Generators are used to perform a wide variety of tasks, and Honda offers a variety of models to suit almost all potential users. Honda generators provide a high quality power source that is reliable and convenient.
• Camping/Recreation/Boating
• Home Standby
• Construction/Rental

HOW QUIET DOES YOUR GENERATOR NEED TO BE?

Honda generators are known for quiet operation. Honda has engineered exceptionally quiet portable models, but offers less costly options that may serve your application at a lower cost. While a camping application may require a super quiet EU series choice, home standby and construction applications would be satisfied with a deluxe or industrial series model, and some applications will allow for the Economy series that do not have the additional features required to provide quiet operation.

IS ELECTRIC START REQUIRED?

Honda engines are renown for the ease of starting, even when only equipped with a manual recoil starter. Honda offers many models with the convenience of electric start for applications that may require remote start or where the ease of electric start is preferred.

DO YOU REQUIRE EASY TRANSPORT?

While all Honda Generators are Portable by definition, many models include standard wheel kits for easy movement of the generator from storage to the work site. Consider the options when selecting the right model for your application.

HOW MUCH POWER DO YOU NEED?

Generators produce AC voltage, very similar to the voltage available in your home, however while your electric utility company produces sufficient power for all your electric powered devices, a portable generator is limited in power output directly relational to the engine horsepower. The amount of power that a generator can produce is rated in watts. Rated power is generally 90% of maximum power as certain components lose efficiency as they are heated from use.

To determine wattage requirements you should determine which devices need to be powered simultaneously and what the starting requirement of the device is. A Wattage calculator is provided to assist you. Remember that with simple "Power Management" techniques, a small generator can provide adequate power for home or recreational applications.

“MAXIMUM” AND “RATED” POWER

A generator should never be operated at its MAXIMUM power output for more than 30 minutes.

RATED power, or the power that a generator can produce for long periods of time, is a more reliable measure of generator power. Typically the RATED power is 90% of the MAXIMUM power.

For Example, a 2500 watt generator produces a MAXIMUM 2500 watts of power. This means at maximum power this generator could light up 25 100-watt light bulbs at the same time. The rated wattage of this generator would be 2300 watts and should only be used to power 23 - 100 watt light bulbs.

When considering your power needs, first determine the highest power application such as a well pump for home power or air compressor for the job site. The power required to start the capacitor motor on these applications will determine the rated power of the generator you should choose for your
application.

TYPES OF LOADS
In the previous example, the light bulbs are the LOAD of the generator. A 2500 watt generator can handle a LOAD of no more than 2500 watts maximum.

RESISTIVE LOADS:  The light bulb example is called a RESISTIVE type load and the POWER it requires is pretty easy to understand. Other RESISTIVE types of LOAD are things like toasters, convection ovens, hot plates, curling irons, coffee makers, stereos and TV's.  RESISTIVE LOADS are usually appliances that do not have electric motors.

RESISTIVE LOADS = 1 x Power

A REACTIVE load contains an electric motor.  Some household appliances like a furnace or refrigerator have internal fans that come on intermittently, so extra wattage/power is needed to start the fan.  Another example is power tools. An appliance or tool with a reactive load may require up to three times as much power (wattage) to START as it does to keep it running. 

Examples of REACTIVE type loads:

• Refrigerators / freezers
• Furnace fans
• Well pumps
• Air conditioners
• Bench grinders
• Air compressors
• Power tools

REACTIVE LOADS = 3 x Power

RESISTIVE LOADS:

The equation shows the relationship between watts, volts and amps in a PURELY RESISTIVE load.  If you know any of the two variables, the third can be calculated.

Example: You want a generator to power a 1000 watt flood light.  The light is 120V and requires 1000 watts of power. Using the equation, we can calculate that the floodlight will draw 8.3 amps of electrical current.

For REACTIVE loads, the equation shows only a general relationship between watts, volts and amps. That's because the power requirements for REACTIVE loads changes with operating conditions. 

Resistive Loads – Volts x Amps = Watts

REACTIVE LOADS:
When determining the proper generator for REACTIVE type loads, you must consider three modes of operation:

STARTING - The electric motor requires more power to start.  The starting power required can be up to THREE times the running amount.

RUNNING - The power required to run the electric motor once it has been started.

LOADED - When the electric motor begins to work (saw begins cutting wood, drill begins drilling thru a wall), its power requirement will increase.  This is not applicable for most household appliances.

DATA TAG:
Method 2 requires a visual inspection of the data tag supplied by the electric motor manufacturer.  All electrical motors have a data tag attached to their bodies that give volts, amps, phase, cycles, hp, and sometimes a code.

Volts (V) - The volts must be either 120 (110-120) or 120/240. 120/240 means that the motor can be wired to operate on 120V or 240V. Honda generators are either 120V or 120/240V.
Amps (A) - Indicates the amps required to RUN the electric motor but doesn't consider STARTING or LOADED power requirements.
Phase (PH) - Honda Generators can power only single phase motors only.
Horsepower (HP) - Rating of how much work an electric motor can perform.
Code - This isn't always provided on the data tag. It represents the maximum STARTING power required of the electric motor.
Cycles (Hz) - All of U.S. electrical appliances run at 60 cycles per second.

LOAD CODE:
Is a letter which represents Amps per Hp to start the motor.  Multiply CODE (amps) times Hp of motor to determine starting amps.  For example: The data tag on our electric motor shows a code of L.  Our motor is 1/3 Hp. An L code is 84 amps per Hp x 1/3 (motor Hp) = 28 amps to start the motor shown.

CODE

AMPS PER HP TO START

CODE

AMPS PER HP TO START

A

26.0

L

83.3

B

29.5

M

93.3

C

33.3

N

104.0

D

37.4

P

116.6

E

41.6

R

133.3

F

46.6

S

149.9

G

52.4

T

166.6

H

59.0

U

186.6

J

66.6

V

more than 186.6

 

 

GENERATOR WATTAGE CALCULATOR

AVERAGE WATTAGE REQUIREMENT GUIDE
(AMPS X VOLTS = WATTS)

Household
Approximate
Wattage Required
For Starting
Approximage
Running Wattage
Requirements

Coffee Maker

600
600
Dishwasher
Cool Dry
540
216
Electric Fry Pan 1500
1500
Electric Range
8-inch element
2100
2100
Microwave Oven 650 watts
1000
1000
Refrigerator or Freezer – Energy Star
1200
132-192
Automatic Washer
1200
1200
Clothes Dryer
Electric
6750
5400
Furnace Fan, gas or fuel oil
1/8 Horsepower 500
300
1/6 Horsepower 750
500
1/4 Horsepower 1000
600
1/3 Horsepower 1400
700
1/2 Horsepower 2350
875
Incandescent Lights as indicated on bulb
as indicated on bulb
Radio
50 to 200 50 to 200
Sump Pump
1/3 Horsepower 1300
800
1/2 Horsepower 2150
1050
Television - Color 300
300
Air Conditioner
10,000 BTU
2200
1500
Contractor
Approximate
Wattage Required
For Starting
Approximage
Running Wattage
Requirements
Air Compressor
1 Horsepower
4500
1600
Bench Grinder
8 inches
2500
1400
Hand Drill
1/2 inch
900
600
High-pressure Washer
1 Horsepower
3600
1200
Circular Saw, Heavy Duty
71/4 inches
2300
1400
Electric Chain Saw
14 inches, 2 Horsepower
1100
1100
Table Saw
10 inches
4500
1800
Drills
3/8 inch 4 amps 600
440
1/2 inch 5.4 amps 900
600
Industrial Motors
Approximate
Wattage Required
For Starting
Approximage
Running Wattage
Requirements
Split Phase
1/4 Horsepower 1700
400
1/2 Horsepower 2600
600
Capacitor Start Induction Run
1/3 Horsepower 975
450
1 Horsepower 2300
1000
Capacitor Start Capacitor Run
1 1/2 Horsepower 4200
1600
Fan Duty
1/4 Horsepower 1200
650
Farm Equipment
Approximate
Wattage Required
For Starting
Approximage
Running Wattage
Requirements
Electric Fence, 25 miles 250
250
Milk Cooler 1800
1100
Milker (vacuum pump),
2 Horsepower
2300
1000
Portable Heater (kerosene, diesel fuel)
50,000 BTU 600
400
90,000 BTU 725
500
150,000 BTU 1000
625
Battery Charger
15 amp 380 380
60 amp with 250-amp boost
1500/5750 1500/5750
100 amp with 300-amp boost
2400/7800
2400/7800
Electric Welder
200 amp AC 9000 9000
230 amp AC, at 100 amp 7800 7800
Air Compressors Approximate
Wattage Required
For Starting
Approximage
Running Wattage
Requirements
1/2 Horsepower 1600 975
1 Horsepower 4500 1600

Computers
Approximate
Wattage Required
For Starting
Approximage
Running Wattage
Requirements
Desktop 600 to 800 600 to 800
Laptop 200 to 250 200 to 250
Monitor (CRT) 200 to 250 200 to 250
Fax 600 to 800 600 to 800
Printer 400 to 600 400 to 600







Policies | Privacy | Terms | Site Map ©2010 Dominion Enterprises